We’re excited to announce that the latest information is now available on our new site, the
Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!">
We’re excited to announce that the latest information is now available on our new site, the Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!

">

We’re excited to announce that the latest information is now available on our new site, the
Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!">
We’re excited to announce that the latest information is now available on our new site, the Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 13 Next »

SUMMARY


GINESYS v11.100.0 software is pretty easy to install and run if you follow the guide carefully. 

It has certain pre-requisites in the system for it to function properly at optimal level. It also has certain important parameters to be checked in relation to database.

Hardware / Operating System Requirements

Component

Server Minimum

Workstation Minimum

Processor

Quad-core x64 architecture 2.8 GHz CPU

Dual-core x64 / x86 architecture 2.0 GHz CPU

Memory

8-GB RAM

4 GB RAM

Hard disk

200 GB or more of available hard disk space

50 GB or more available hard disk space

HDD count

Minimum 2 same capacity HDD

1 nos.

UPS

Online UPS with 30 minutes backup

 Offline UPS with 15 minutes backup minimum

Operating System

Windows Server 2008 R2

Windows 7 (Service Pack 1)

Internet

2 mbps stable connection

Nil


Important Notes:


  1. Above requirements are the minimum requirements for a 3-5 user typical workload.
  2. Actual requirements may vary based on your product configuration, high availability requirements and work load.
  3. Running GINESYS on less than minimum system configuration will have adverse effects on performance.
  4. It is recommended to run GINESYS on good quality branded servers and not on assembled servers.
  5. Desktop operating systems are strictly not supported on Server.
  6. Lower versioned operating systems than mentioned for Server and Workstation are strictly not supported. E.g. Windows 2003, Windows 2008 on Server, Windows XP/Vista on desktop will not be supported.
  7. Service packs and updates as released by Microsoft from time to time should be updated on systems on a regular basis
  8. Anti-Virus and Network Security software if installed on the server will have to be configured and maintained by the customer so that necessary communications to and from GINESYS Server is allowed. GINESYS support if anticipates that any issue is being caused by such third party software may request the client to uninstall the concerned software while working on the ticket.

List of communications to and from GINESYS Server

  1. OUTBOUND to Web Database (hosted by Customer or GINESYS) typically on TCP Port 1443
  2. OUTBOUND to GSL Licensing Server (lc.ginesys.co.in) typically on non-default SQL Server Port 51433
  3. OUTBOUND to GSL Patch Update Server (update1.ginesys.in / update2.ginesys.in) on ACTIVE Mode FTP port 21
  4. INBOUND to GINESYS Application Server on IIS typically on HTTP Port 80 (for Web Application)
  5. INBOUND to GINESYS Application Server for accessing application from File Share on TCP Port 445, 139
  6. A steady internet connection is required for smooth operations and also remote support from GINESYS. Please note that support ticket will be kept on hold unless a steady 2 mbps connection is provided.

What are the software pre-requisites for installation?

Component

Installation Process

Server / Workstation / Both

Operating Systems (OS)


For Server: Windows 2008 /Windows 2008R2 / Windows 2012.


For WK: Windows7 / Windows 8/

Windows 10.

Manual install

Both

Microsoft .NET Framework 4.5

Windows 7: GINESYS Installer  

Windows 2008 R2:  GINESYS Installer  

All other OS:  Manual install

Both

Internet Information Server (IIS)

GINESYS IIS Installer 

Server

IMPORTANT

Important Notes regarding enabling IIS:

Note: Depending upon the Operating Software (OS) you use, some of these prerequisites may already be present in your system. However, please check out if each of the prerequisites are already enabled or installed.

Note: The servers must be 64 bit machines by default but terminals may be 32 bit or 64 bit as required. However, if any of your terminals run on Windows 10 then the machine has to be a 64 bit one.

Note:GINESYS has provided a batch file for automatic installation of IIS if it is not installed in your intended machine. This .bat file can be found at the following location:

(Root directory of your installation CD or DVD)/IISConfig/InstallIIS.exe

In case the installer cannot run for some reason, please note that you must enable IIS through Server Roles option in the Add Roles Wizard; if you are running Windows 2008 / Windows 2008R2 / Windows 2012 for servers.

Please follow the illustrations given below:



IIS has to be mandatorily enabled for GINESYS V11.100.0 because presently, only the Retail, Web Services and Shipment tracking related operations are running through IIS. But modules which are running in D2k platform are going to be converted gradually into Web platform in near future. So, it would be safe to configure the IIS from day one.


It is important to note that ASP.NET under IIS feature must be enabled in both servers and terminals.


The v11.100.0 can either be newly installed in a system or be migrated from an old one, below are given the steps for making new installations as well as migrating from previous version.



There are also a few steps which need to be executed for both new installations and migrating from previous versions creating a new database and finally migrating from previous versions keeping the existing database.

Note: During GINESYS installation only the 'WebServer (IIS)' role is to be checked. 

New Installations

Oracle 12c Standard Edition must be installed previously if it is a fresh installation or the database is being migrated to a newer upgrade. Please remember to check for previous Oracle installations if any and uninstall them first.

Migrating from previous versions creating a new database

You may wish to create a new Oracle 12c database in the interests of enhanced performance. In that case follow the steps given below to uninstall the previous database.

IMPORTANT

Note: When you are migrating from previous versions, you must go through the process of deleting or uninstalling the previous GINESYS Software if you are migrating from a lower version to v11.100.0.

Taking back-up and checking it is mandatory; before uninstallation of software.


  1. You must uninstall the previous GINESYS version from Add/Remove Programmes.
  2. Delete the GINESYS folder structure from the drive where you have installed it.
  3. Delete all GINESYS related schedulers from the command prompt (cmd) with the command <<sc delete <name of scheduler>>>. The list of services run in GINESYS are given below:
    1. GINESYS Scheduler Service
    2. GINESYS SMS Service
    3. GINESYS Email Service
    4. GINESYS Licensing Service
    5. GINESYS Planning Service
  4. Delete the previous ODAC (Oracle Data Access Components) 11g by executing the following steps:
    1. Open Command Prompt; remember to run it as Administrator.
    2. Locate the folder where ODAC has been installed (eg: c:\ODAC64).
    3. Once the cursor changes, run the command c:\ODAC64 uninstall.bat all odac (Note that “odac” over here is the home name, the same name used while installing ODAC). This uninstalls all the components.
  5. Delete the previous ODAC (Oracle Data Access Components) 10g by executing the following steps:
    1. Uninstall all Oracle components using the Oracle Universal Installer (OUI).
    2. Run regedit.exe and delete the HKEY_LOCAL_MACHINE/SOFTWARE/Oracle key. This contains registry entries for all Oracle products.
    3. If you are running 64-bit Windows, you should also delete the HKEY_LOCAL_MACHINE/SOFTWARE/Wow6432Node/Oracle key if it exists.
    4. Delete any references to Oracle services left behind in the following part of the registry (HKEY_LOCAL_MACHINE/SYSTEM/CurrentControlSet/Services/Ora*). It should be pretty obvious which ones relate to Oracle.
    5. Reboot your machine.
    6. Delete the "C:\Oracle" directory, or whatever directory is your ORACLE_BASE.
    7. Delete the "C:\Program Files\Oracle" directory.
    8. If you are running 64-bit Windows, you should also delete the "C:\Program Files (x86)\Oracle" directory.
    9. Remove any Oracle-related subdirectories from the “C:\ProgramData\Microsoft\Windows\Start Menu\Programs\" directory.
    10. Empty the contents of your "C:\temp" directory.

Migrating from previous versions keeping the existing database


Otherwise, if the existing 10g database has to be maintained, the 10g database can exist as it is, provided the OS involved is Windows 7 or Windows Server 2008.

IMPORTANT

Note: that you must have ODAC 12c even if your database 10g

Note: When you are migrating from previous versions, you must go through the process of deleting or uninstalling the previous GINESYS Software if you are migrating from a lower version to V11.100.0.

  1. Taking back-up (especially of environment variables) and checking it is mandatory; before uninstallation of software.
  2. You must uninstall the previous GINESYS version from Add/Remove Programs.
  3. Delete the GINESYS folder structure from the drive where you have installed it.
  4. Delete all GINESYS related schedulers from the command prompt (cmd) with the command <<sc delete <name of scheduler>>>. The list of services run in GINESYS are given below:
    1. GINESYS Scheduler Service
    2. GINESYS SMS Service
    3. GINESYS Email Service
    4. GINESYS Licensing Service
    5. GINESYS Planning Service
  5. Delete the previous ODAC (Oracle Data Access Components) 10g by executing the following steps:
    1. In the command prompt (cmd) type <<cd <drive where ODAC is existing>\ODAC64>>
    2. In the current drive i.e. <drive where ODAC is existing>\ODAC64 – type <<uninstall all ODAC>>
    3. Similarly change drive for ODAC32, and uninstall it.
  6. Go to Regedit>>software>>wow64>>oracle and delete odp.net file
  7. Restart the System
  8. Run the Server Pack Setup from the CD
  9. Run Getting Started
    1. Choose option “I have connected to an existing database
    2. Ensure that your test connection is successful
  10. Generate License request from license manager and mail key to license@gsl.in
  11. Activate license from License Manager
    1. Search online for the key and accept and then check POS users
  12. If you get a connection problem to the Primary Database then open the License manager and define the domain in the last tab.
  13. Start the License service and wait for 30 seconds
  14. Run HO AutoUpdate
    1. Stop all services from the Services and Processes tab
    2. Update till latest
  15. Open software location
    1. Locate Webdb updater
    2. Run webdb update
  16. Now your software is ready for use.

New Installations and Migrating from previous version with new database

Now we can start installing the software from the CD provided.

Find the Setup.exe on your CD drive.


Now you’ll be taken to the Installation Wizard


System information and mandatory prerequisite information (install/ de-install) will appear.


Please follow the steps given above to enable IIS if you get this alert.


Please enable .NET framework 4.5 if you get this alert.


Uninstall old ODAC11 and ODAC12c will automatically be installed by the GINESYS Installer.


If it is a migration scenario, uninstall the old GINESYS version, when you get this message.


If you have already installed and de-installed the prerequisite services and software, then you will find the License Agreement.


Once you accept the licensing terms; the installation process will continue, you need to provide a User Name and a Company Name and choose the “Anyone who uses this machine” option. Then click on Next.


Then choose the features you wish to install by checking the boxes. Click on the Next option.



It displays the Installation Location and the features installed. If you feel all details are correct, click on Next.


Now your GINESYS installation will be validated and configured.


Now the installer will install some of the prerequisite software/utilities

SAP Crystal Reports Runtime 13 version 13.0.8 or above


SQL Server 2012 Native Client

SQL Server 2012 CLR Types

SQL Server 2012 Shared Management Objects


SQL Server 2012 Command Line Utilities


Then your installation is complete and your software is ready for use.


Make a final check to see that all GINESYS related software and the other installations from the pack are completed properly.

Check the new folder structure.

Check your database installation (whether 10g or 12c).


Getting Started

Right after the physical installation of the software, the GINESYS logo will appear on your screen. Clicking on this logo will take you to the GINESYS Launchpad. The GINESYS Launchpad is a new Dashboard UI for GINESYS v11.100.0. The Getting Started tab is a component of this UI and will be active only once after a new installation to allow users to connect to their database, provide company details and install some of the pre-requisites.


How does getting started work?

Steps

Figure

After completion of running the GINESYS Installation Wizard, the GINESYS Launchpad appears on clicking the GINESYS logo on your screen. It has only one active tab at this stage i.e. the Getting Started.

On clicking Getting Started, you will reach the Welcome screen. Click on the “Next” button. 

The next screen is about database connection.

Please provide the following:

Host: The UI by default shows the Machine (Server) Name.

Port: Must be 1521


Service: Must be GINESYS respectively.

User (with Data Base Administrator privilege): May be anything (recommended user - SYSTEM)

Password: May be anything (recommended password - SYSPWD)

This would allow easy management of the database and handling of support issues.

Correctly locate Oracle SQLCMD Command Line Utility by browsing; if you have installed your database correctly then it would be in the shown path only. Click on the Next button.

The next screen, provides you the following options:

A new installation with a new database

Connect to an existing database

Restore the old database


After making the above decision and clicking next, if you have chosen a new installation, you will get a new screen. Here you can put in your Company Information.

IMPORTANT

This is a very important stage of installation, please be careful about the information you put in here, because you will not be able to change the details later.


Schema Password - May be anything (recommended password - gmpl) .

GINESYS Admin name - May be anything (recommended password - admin)

GINESYS Admin password - May be anything (recommended password - admin).

Start Date would depend on the financial calendar that your company follows.

IMPORTANT

Note : Usually the financial year is 1st April current year to 31st March next year.


Click on the Next button.

Then the next step of Getting Started shows information about the installations made by it.

Finally, you get the Completion Screen, which prompts you to apply your GINESYS License and open the License Manager.

For new installation, click Yes and install the license.

Click on the Finish button to complete the process and close the Application.


Workstation installation

Since GINESYS runs on Client-Server architecture, it is necessary to carefully install the clients or workstations. Follow steps given below to successfully install them.

Steps

Figure

Map the nodes to the Application Server of the GINESYS software.

In the Application Server, Click on the WKSETUP folder.

In the WKSETUP folder, run the setup.exe as administrator.

This will open the GINESYS Workstation Welcome Screen. Click on Next.

In the next screen, provide the following details and click Next.
  1. User name
  2. Company Name
  3. Select the option of - Anyone who uses the Computer or Only for me (user) (Recommended option - Anyone who uses the Computer).

Next the features to be installed are selected and the Destination folder is provided. Click on Next.

All settings for the installation are displayed on this screen. If any thing needs to be changed - click on Back; if everything is satisfactory - click Next.

The Workstation Configuration happens automatically.

ODAC 64 bit is then installed.

Then the installation is complete and ready to be used.