We’re excited to announce that the latest information is now available on our new site, the
Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!">
We’re excited to announce that the latest information is now available on our new site, the Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!

">

We’re excited to announce that the latest information is now available on our new site, the
Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!">
We’re excited to announce that the latest information is now available on our new site, the Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 12 Next »

Problem


In Ginesys Report module, while trying to run any report from Home tab , an error appeared as follows.

Error: The requested name is valid, but no data of the requested type was found
Server stack trace:
at System.Net.Dns.GetAddrInfo(String name)
at System.Net.Dns.InternalGetHostByName(String hostName, Boolean includeIPv6)
at System.Net.Dns.GetHostAddresses(String hostNameOrAddress)
at System.Runtime.Remoting.Channels.RemoteConnection.CreateNewSocket()
at System.Runtime.Remoting.Channels.SocketCache.GetSocket(String machinePortAndSid, Boolean openNew)
at System.Runtime.Remoting.Channels.Tcp.TcpClientTransportSink.SendRequestWithRetry(IMessage msg, ITransportHeaders requestHeaders, Stream requestStream)
at System.Runtime.Remoting.Channels.Tcp.TcpClientTransportSink.ProcessMessage(IMessage msg, ITransportHeaders requestHeaders, Stream requestStream, ITransportHeaders& responseHeaders, Stream& responseStream)
at System.Runtime.Remoting.Channels.BinaryClientFormatterSink.SyncProcessMessage(IMessage msg)

Screenshot of the Error Message :

Further Observation :

  • Entire Server reinstalled and Web report also re-installed with the help of Ginesys Report folder.

  • Entire Server migrated to another system and web report also re-installed with Ginesys Report folder.

CAUSE


  • Schedule Remoting Host path details is wrong ( protocol or hostname/IP ) under Scheduler Settings of Server tab.

Resolution


  • Set the Schedule Remoting Host path details properly with running report server configuration (Protocol, Hostname or IP,Port).

  • Then save the settings and click on Apply.