SYMPTOMS
...
Requested by: Jit Chatterjee
Sometimes the service failed to start in windowsWindows.
CAUSE
...
The probable cause of the above issue is the service waits in a queue for windows Windows other services.
RESOLUTION
...
Follow the given steps to resolve the issue -
Steps:
- From start menu, open Services application and search for the GINESYSPlanningService.
- Inside Property, go to the General tab and check the Startup type. Set it Automatic (Delayed Start).
- Set the Administer account and Password in Log On tab.
- Set the First failure, Second failure and Subsequent failure as Restart the Service for all three options in the Recovery tab.
Note |
---|
Note: The same steps we have to apply if SMTP Auto Mail Service failed to start automatically. |
This should resolve your issue, in case you face it again please contact our Ginesys Care portal - https://care.ginesys.in/
...