We’re excited to announce that the latest information is now available on our new site, the
Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!">
We’re excited to announce that the latest information is now available on our new site, the Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!

">

We’re excited to announce that the latest information is now available on our new site, the
Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!">
We’re excited to announce that the latest information is now available on our new site, the Ginesys One Wiki!. Visit the site for up-to-date resources and insights. We look forward to continuing to support you there!

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 19 Next »

Organization is the other term for the word Company which GINESYS uses. While earlier GINESYS operated with a single company/organization concept, currently it operates with multiple unit under a single umbrella concept. This unified entity, to which the operating units belong, are known as Organization Group.

What is the purpose of this form?

Apart from the preliminary Company Information that is provided at the time of creation of the Company during installation, additional company details like the Company's business address details, statutory details and configuring of some of the overall functions of the software can be captured through this.

Prerequisites

  1. The user's role must have the Edit application operation enabled for the Organization Group feature in Admin - Organization - Hierarchy through Roles in Ginesys Web - Admin - Security.

Step-by-step guide

  1. Go to Ginesys Web > Admin > Organisation > Hierarchy > Organisation Group.
  2. Apart from the logo, the  company and the company address in the center of the page, an Edit Info button is displayed in the bottom right hand corner of the Organisation Group page. 
  3. On clicking the Edit Info button, the Edit Organisation Group window appears.
FieldDescription

Organization Information

NameName of the company or Organization Group. This is the umbrella entity under which the different organizational units and sites are created.
OU Default NameTag the Default Organization Unit (OU), so that in case of multiple OU, auto entries getting posted from managed sites can have an Organization unit to create some of the financial and operational documents as these sites are not assigned to any particular OU.
InitialThese two fields basically show some company details with no real functional importance.

Short name
Item PrefixIt is a prefix unique to the items belonging to this Organization Group.
System Start DateThis is a display field whose value shows the date of installation of the software.

General tab

Communication section
AddressAddress of the company or Organization Group.
Phone NumberPhone Number of the company or Organization Group
Fax NumberFax Number of the company or Organization Group
EmailGeneral email of the company or Organization Group
Web siteWeb site of the company or Organization Group
ISD CodeISD code of the company or Organization Group.
Background Color picker

Allows you to change the background color of the logo of your company.

Default value - #414141

Effect seen in the Logo Preview, GINESYS Web login page, GINESYS Web Header tab.

Note: In case no logo is provided, the GINESYS Logo will available.

The image should be a rectangle with preferable a 1:5 ratio.

Upload ImageThe Browse button opens a list of files from which you can select and uload your logo
Image previewThis shows a preview of how an image would look.
Reset DefaultThis button restores the default settings for the logo - the GINESYS logo appears.
Close buttonCloses the window after confirmation of saving the changes.

Profile tab

Item Creation
For change in Aging PeriodBarcode / Item creation behavior - depending on changes in Ageing Period, Purchase Rates and Supplier/Vendor - using existing codes or creating new barcodes.
For change in Standard Rate
For Change in Supplier / Vendor
Split Item Creation Date

Sometimes a set of items may be split into distinct ones and sold separately. The date of creation of such item may be taken as -

  • Original Item date
  • Split date
GS1 Barcode PrefixA GS1 Barcode Prefix is a unique identity number furnished to just one company—and it's part of every barcode and identification number created in that particular company. It's a way to uniquely identify a brand in the global supply chain.
Others
Profit and Loss Ledger for B/S postingHere the user needs to select the ledger where profit and loss of transactions would be posted for reflection in the balance sheet.
Inter Site Reconciliation LedgerSelect the ledger where the Inter Site movement of stock will be posted after reconciliation.
Cash Discount Received ledgerSelect the ledger where the cash discounts shall be entered.
Default Matrix CategoryThe user can select the default category criterion of the items that will be used for report creation.
Maximum No. of Cubes to be created per Master Cube

An OLAP cube is a data structure that can handle large amounts of data while providing users with searchable access to any data points as needed to handle the widest variety of questions that are relevant to a user’s area of interest.

This field allows the selection of the maximum number of cubes in GINESYS.

Auto Issue LR on Creation (checkbox)This checkbox, on selection, automates the entry of the LR issuance.
Allow receive entry against partial Gate Entry LR (checkbox)This checkbox, on selection, allows the user to make GRCs against partial gate entry documents.
Password Policy
Enforce Strong Password 
It is a mandatory field. It is a drop-down to enforce the usage of a strong password. If 'Yes' is selected from the list of values, it will ensure that the following conditions are fulfilled for each password subsequently created. The default for this is set to 'No'
  • Minimum 8 characters required
  • At least 1 uppercase alphabet [A-Z] required
  • At least 1 lowercase alphabet [a-z] required
  • At least 1 digit [0-9] required
  • At least 1 Non-alphanumeric [~!@#$%^&*_-+=`|\(){}[]:;"'<>,.?] character required 
    Note: Front slash(/) and Space key are not allowed as password characters.

Important information regarding applicability of Password configuration

  1. Both the configuration mentioned above will be applicable to Admin (Head Office) and System (store) as well.
  2. Both the configuration available above will be applicable to all types of users, i.e., Head Office (internal as well as partner users for shipment tracking) and POS users (both centrally and locally managed).

Caution:

If immediately after this patch update, you enforce password expiry (in days) option, then all users will have to change their password before logging into Ginesys HO and POS. The system will capture the last password changed information only once the user changes their password post this patch update.
We recommend you to implement this rule by considering your operations. Like sending an instruction to all the users to change the password with a deadline date, else they will be forced to change the password as soon as you enable password expiry.
The Password expiry (in days)

The Password expiry (in days) is not mandatory and can be kept blank. But once defined, it can only be a whole number between 1 and 999. This basically means that, after the number days that are specified in this field has passed the password will have to be reset.

  • If left blank, it will never expire until its explicitly changed.
  • If the password expiry is set to one (1) day then the password will have to be reset everyday

    If suppose a user changes the password on 13th November, 2017, then he will be allowed to login until 14th November, 2017. When he tries to login, on 15th November, he will be asked to change the password.


  • If this number happens to be two(2), then the password will mandatorily have to be re-set after every two days; including the date when the first password is set. 

To go back to the main page click on Managing Organization Hierarchy

  • No labels